Heating load in Spruce Grove

A home in Spruce Grove has to be heated against a design temperature of −35.5 °C. That figure is measured, not modelled: it is the 1st percentile of daily minimum temperature over 19 years at Edmonton Stony Plain Cs, 13 km away.

Design temperature −35.5 °C
Heating degree days 5,466
Coldest month Jan
Coldest night on record −47.3 °C

How many kilowatts

Heating power needed at the design temperature, in kilowatts, for a detached house. Pick the row that matches the building.

Construction Detached Semi-detached Terraced Top-floor flat Mid-floor flat Ground-floor flat
Uninsulated, single glazed 35.8 kW 31.4 kW 27.8 kW 30.5 kW 14.9 kW 18.2 kW
Unfilled cavity, early double glazing 24.2 kW 20.9 kW 18.2 kW 17.7 kW 10.7 kW 13.5 kW
Insulated to 1980s standards 13.8 kW 12.4 kW 11.3 kW 10.7 kW 7.7 kW 9.8 kW
Modern, roughly 1995-2010 8.5 kW 7.8 kW 7.2 kW 6.9 kW 5.2 kW 6.3 kW
Current building regulations 6.5 kW 6.0 kW 5.5 kW 5.4 kW 4.0 kW 4.9 kW
Passive house 3.8 kW 3.5 kW 3.2 kW 3.0 kW 2.0 kW 2.7 kW

Where the heat goes

For a 120 m2 detached house of this construction, at the design temperature.

Element W Share
Walls 4,559 33%
Roof 1,332 10%
Ground floor 899 7%
Windows 2,597 19%
Thermal bridges 763 6%
Ventilation and draughts 3,680 27%
Heating load 13,830 13.8 kW

Calculate it for your own home

The climate half of this is measured. The building half is yours to supply.

Heating load

Monthly mean temperature

JanFebMarAprMayJunJulAugSepOctNovDec
°C −12.0 −10.1 −4.6 3.0 10.2 14.2 16.5 15.8 10.6 3.8 −4.9 −11.3