Heating load in Prince Albert

A home in Prince Albert has to be heated against a design temperature of −37.0 °C. That figure is measured, not modelled: it is the 1st percentile of daily minimum temperature over 29 years at Prince Albert Glass Field, 7 km away.

Design temperature −37.0 °C
Heating degree days 5,247
Coldest month Jan
Coldest night on record −46.1 °C

How many kilowatts

Heating power needed at the design temperature, in kilowatts, for a detached house. Pick the row that matches the building.

Construction Detached Semi-detached Terraced Top-floor flat Mid-floor flat Ground-floor flat
Uninsulated, single glazed 36.7 kW 32.2 kW 28.6 kW 31.4 kW 15.3 kW 18.7 kW
Unfilled cavity, early double glazing 24.9 kW 21.4 kW 18.7 kW 18.2 kW 11.0 kW 13.8 kW
Insulated to 1980s standards 14.2 kW 12.8 kW 11.6 kW 10.9 kW 7.9 kW 10.0 kW
Modern, roughly 1995-2010 8.7 kW 8.0 kW 7.4 kW 7.0 kW 5.3 kW 6.4 kW
Current building regulations 6.7 kW 6.1 kW 5.7 kW 5.5 kW 4.1 kW 5.0 kW
Passive house 3.9 kW 3.6 kW 3.3 kW 3.1 kW 2.1 kW 2.8 kW

Where the heat goes

For a 120 m2 detached house of this construction, at the design temperature.

Element W Share
Walls 4,683 33%
Roof 1,368 10%
Ground floor 923 7%
Windows 2,668 19%
Thermal bridges 784 6%
Ventilation and draughts 3,779 27%
Heating load 14,204 14.2 kW

Calculate it for your own home

The climate half of this is measured. The building half is yours to supply.

Heating load

Monthly mean temperature

JanFebMarAprMayJunJulAugSepOctNovDec
°C −16.4 −14.1 −7.1 2.7 10.6 15.7 18.3 17.0 11.1 3.1 −6.4 −14.1

Where these numbers come from