Heating load in North Bay

A home in North Bay has to be heated against a design temperature of −29.6 °C. That figure is measured, not modelled: it is the 1st percentile of daily minimum temperature over 29 years at North Bay, 6 km away.

Design temperature −29.6 °C
Heating degree days 4,304
Coldest month Jan
Coldest night on record −38.0 °C

How many kilowatts

Heating power needed at the design temperature, in kilowatts, for a detached house. Pick the row that matches the building.

Construction Detached Semi-detached Terraced Top-floor flat Mid-floor flat Ground-floor flat
Uninsulated, single glazed 32.0 kW 28.0 kW 24.9 kW 27.3 kW 13.3 kW 16.3 kW
Unfilled cavity, early double glazing 21.6 kW 18.7 kW 16.3 kW 15.8 kW 9.6 kW 12.0 kW
Insulated to 1980s standards 12.4 kW 11.1 kW 10.1 kW 9.5 kW 6.8 kW 8.7 kW
Modern, roughly 1995-2010 7.6 kW 6.9 kW 6.4 kW 6.1 kW 4.6 kW 5.6 kW
Current building regulations 5.8 kW 5.3 kW 5.0 kW 4.8 kW 3.6 kW 4.4 kW
Passive house 3.4 kW 3.1 kW 2.8 kW 2.7 kW 1.8 kW 2.4 kW

Where the heat goes

For a 120 m2 detached house of this construction, at the design temperature.

Element W Share
Walls 4,075 33%
Roof 1,190 10%
Ground floor 804 7%
Windows 2,321 19%
Thermal bridges 682 6%
Ventilation and draughts 3,288 27%
Heating load 12,360 12.4 kW

Calculate it for your own home

The climate half of this is measured. The building half is yours to supply.

Heating load

Monthly mean temperature

JanFebMarAprMayJunJulAugSepOctNovDec
°C −11.7 −10.3 −4.3 3.2 11.5 16.5 18.9 17.9 13.5 6.5 −0.5 −7.2